Variable |
Description |
ATLAUX |
ATLMDT |
ATLRPC |
ATLTFC |
ATLTGC |
ATLTRT |
ATLMMG |
has_MixerEnvelope |
additional mixer module optional (option valid? 1=yes, 0=no) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
wago_node_nb |
Number of wago modules |
1 |
2 |
2 |
0 |
2 |
2 |
2 |
Profibus_Monitoring |
Profibus Monitoring deployed (1=yes, 0=no) |
1 |
1 |
1 |
0 |
1 |
0 |
1 |
CANbus_Monitoring |
CANbus ELMB status Monitoring deployed (1=yes, 0=no) |
0 |
1 |
1 |
0 |
1 |
0 |
1 |
subdetector |
System Name |
AUX |
MDT |
RPC |
TFC |
TGC |
TRT |
MMG |
sub_short |
System Short Name |
AUX |
MDT |
RPC |
TFC |
TGC |
TRT |
MMG |
has_Mixer |
standard module optional (option valid? 1=yes, 0=no) |
0 |
1 |
1 |
0 |
1 |
1 |
1 |
has_Pump |
standard module optional (option valid? 1=yes, 0=no) |
0 |
1 |
1 |
0 |
1 |
1 |
0 |
has_Distribution |
standard module optional (option valid? 1=yes, 0=no) |
0 |
1 |
1 |
0 |
1 |
1 |
1 |
has_PreDistribution |
standard module optional (option valid? 1=yes, 0=no) |
0 |
0 |
0 |
0 |
0 |
1 |
0 |
has_Purifier |
standard module optional (option valid? 1=yes, 0=no) |
0 |
0 |
1 |
0 |
1 |
1 |
0 |
has_Absorber |
standard module optional (option valid? 1=yes, 0=no) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_Exhaust |
standard module optional (option valid? 1=yes, 0=no) |
0 |
1 |
1 |
0 |
0 |
1 |
0 |
has_Analysis |
standard module optional (option valid? 1=yes, 0=no) |
1 |
1 |
1 |
0 |
1 |
1 |
1 |
Analysis_chains_count |
number of Analysis modules |
4 |
1 |
2 |
n/a |
1 |
1 |
2 |
Analysis_chains_start |
Option to set first chain number |
3 |
1 |
1 |
n/a |
1 |
1 |
1 |
has_Humidifier |
standard module optional (option valid? 1=yes, 0=no) |
0 |
1 |
1 |
0 |
0 |
0 |
0 |
has_Membrane |
standard module optional (option valid? 1=yes, 0=no) |
0 |
0 |
0 |
0 |
0 |
1 |
0 |
has_Recovery |
non standard module (valid only in CMS Recovery gas system) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_Liquifier |
standard module optional (option valid? 1=yes, 0=no) |
0 |
0 |
0 |
0 |
1 |
0 |
0 |
has_IDFlushing |
non standard module (valid only in ATLAS) |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
has_IDFlushingN2 |
non standard module (valid only in CMS) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_GasSystem |
standard module optional in case of AUX there are no gas system option but option will be set to TRUE (to allow profibus HMI generation) (option valid? 1=yes, 0=no) |
1 |
1 |
1 |
0 |
1 |
1 |
1 |
has_Envelops |
standard module optional (option valid? 1=yes, 0=no) |
0 |
0 |
0 |
0 |
1 |
1 |
0 |
has_Environmental |
standard module optional (option valid? 1=yes, 0=no) |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
has_Primary |
standard module optional (option valid? 1=yes, 0=no) |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
has_CF4AbCF4 |
non standard module (used only in CMS CF4 Recovery gas system) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_CF4AbCO2 |
non standard module (used only in CMS CF4 Recovery gas system) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_CF4Membrane |
non standard module (used only in CMS CF4 Recovery gas system) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_CF4Pump |
non standard module (used only in CMS CF4 Recovery gas system) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_CF4Recovery |
non standard module (used only in CMS CF4 Recovery gas system) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_GasSystemB |
non standard module (valid only in ATLAS TFC gas system) |
0 |
0 |
0 |
1 |
0 |
0 |
0 |
has_DistributionB |
non standard module (valid only in ATLAS TFC gas system) |
0 |
0 |
0 |
1 |
0 |
0 |
0 |
has_PumpB |
non standard module (valid only in ATLAS TFC gas system) |
0 |
0 |
0 |
1 |
0 |
0 |
0 |
has_Injection |
non standard module (valid only in ATLAS TFC gas system) |
0 |
0 |
0 |
1 |
0 |
0 |
0 |
has_Circulation |
non standard module (valid only in ATLAS TFC gas system) |
0 |
0 |
0 |
1 |
0 |
0 |
0 |
has_TROpenSystem |
TROpen system part of TRT |
0 |
0 |
0 |
0 |
0 |
1 |
0 |
has_XenonDirect |
valid only in TRT |
0 |
0 |
0 |
0 |
0 |
1 |
0 |
has_SciFiSystem |
non standard gas system (valid only in LHCb ) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
dipManagerNumber |
Dip Manager Number |
8 |
5 |
3 |
6 |
7 |
4 |
9 |
has_AnalysisO2 |
Analysis O2 FS alarm |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_AnalysisH2O |
Analysis H2O FS alarm |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_AnalysisCO2 |
Analysis CO2 FS alarm |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_AnalysisInfraRed |
Analysis Infrared FS alarm |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_XenonRecuperation |
Purifier Recuperation gas module (only valid for TRD) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Analysis_FA_version |
logic production version |
1.0 |
1.0 |
1.0 |
n/a |
1.0 |
n/a |
1.0 |
IDFlushing_FA_version |
logic production version |
1.0 |
n/a |
n/a |
n/a |
n/a |
n/a |
n/a |
has_Compressor |
Gas recuperation Compressor module(option valid? 1=yes, 0=no) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
has_IDEPAnalysis |
IDEP Analysis module (option valid? 1=yes, 0=no) |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
IDEPAnalysis_FA_version |
logic production version |
1.0 |
n/a |
n/a |
n/a |
n/a |
n/a |
n/a |
has_UTFlushing |
has_UTFlushing module(option valid? 1=yes, 0=no) |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
GasSystem_Monitoring |
Soft-FE Gas System Data Analysis |
0 |
1 |
1 |
0 |
1 |
0 |
0 |
Purifier_FA_version |
Production Purifier logic FA version (=0 not reviewed yet) |
n/a |
1.1 |
1.1 |
n/a |
1.1 |
0 |
1.1 |
GasSystem_FA_version |
logic production version |
n/a |
1.0 |
1.0 |
n/a |
1.0 |
n/a |
1.0 |
Distribution_FA_version |
logic production version |
n/a |
1.0 |
1.0 |
n/a |
1.0 |
n/a |
1.0 |
Option_BuffPressRegul |
Buffer pressure regulation (Mixer option)-variable used in Exhaust trends(option valid? 1=yes, 0=No) |
n/a |
0 |
0 |
n/a |
0 |
1 |
0 |
Mixer_param |
Mixer parameters used in profibus HMI only(nber of lines) |
n/a |
2 |
3 |
n/a |
2 |
3 |
3 |
Pump_param |
Pump parameters used in profibus HMI only(architecture, nber of pump lines) |
n/a |
B,2 |
A,3 |
n/a |
A,2 |
A,2 |
n/a |
Mixer_FA_version |
logic production version |
n/a |
1.0 |
1.0 |
n/a |
1.0 |
1.0 |
1.0 |
Distribution_param |
Distribution parameters used in profibus HMI only(architecture, nber of Groups, option PCVxx26, pnl height) |
n/a |
A,1,1,639 |
A,1,1,639 |
n/a |
A,1,1,396 |
A,1,0,198 |
A,1,0,198 |
PumpReg_Option |
Pressure Regulation handle by the Pump Pressure PT4004 used in Pump and Distribution(0=No regulation from pump, 1= Regulation from Pump) |
n/a |
0 |
0 |
n/a |
0 |
0 |
0 |
Pump_FA_version |
logic production version |
n/a |
1.0 |
1.0 |
n/a |
1.0 |
1.0 |
1.0 |
Purifier_count |
Number of Purifier modules |
n/a |
1 |
3 |
1 |
1 |
1 |
1 |
Exhaust_param |
Exhaust parameters used in profibus HMI only(panel height) |
n/a |
198 |
198 |
n/a |
n/a |
198 |
n/a |
Exhaust_FA_version |
logic production version |
n/a |
1.0 |
1.0 |
n/a |
n/a |
1.0 |
1.0 |
Humidifier_FA_version |
logic production version |
n/a |
1.0 |
1.0 |
n/a |
n/a |
n/a |
1.0 |
has_Distr_envelop |
has Distribution Gas Envelop (1=yes, 0=no) |
n/a |
0 |
0 |
0 |
1 |
0 |
0 |
has_SubDetect_envelop |
has Sub Detecotor a Gas Envelop (1=yes, 0=no) |
n/a |
0 |
0 |
0 |
0 |
1 |
0 |
SecChambPT |
2nd chamber pressure transmitters PTxx04_2 used in Pump and Distribution(option valid? 1=yes, 0=No) |
n/a |
0 |
0 |
n/a |
0 |
0 |
0 |
Dist_N2Flow |
Total N2 flow for distribution racks FT6020 (1=FT6020 present, 0=FT6020 Absent) |
n/a |
0 |
0 |
n/a |
0 |
0 |
0 |
Liquifier_FA_version |
logic production version |
n/a |
n/a |
n/a |
n/a |
1.0 |
n/a |
n/a |
Distr_rack61_chls_nb |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
6 |
n/a |
n/a |
Distr_rack62_chls_nb |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
12 |
n/a |
n/a |
Distr_rack63_chls_nb |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
6 |
n/a |
n/a |
Distr_rack64_chls_nb |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
6 |
n/a |
n/a |
Distr_rack65_chls_nb |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
6 |
n/a |
n/a |
Distr_rack66_chls_nb |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
12 |
n/a |
n/a |
Distr_rack67_chls_nb |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
6 |
n/a |
n/a |
Distr_rack68_chls_nb |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
6 |
n/a |
n/a |
Distr_rack61_label |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
EM-TGC-L0-C-1 |
n/a |
n/a |
Distr_rack62_label |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
EI-TGC-L4-C-1 |
n/a |
n/a |
Distr_rack63_label |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
EM-TGC-L4-C-1 |
n/a |
n/a |
Distr_rack64_label |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
EM-TGC-L8-C-1 |
n/a |
n/a |
Distr_rack65_label |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
EM-TGC-L0-A-1 |
n/a |
n/a |
Distr_rack66_label |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
EM-TGC-L4-A-1 |
n/a |
n/a |
Distr_rack67_label |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
EI-TGC-L4-A-1 |
n/a |
n/a |
Distr_rack68_label |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
EM-TGC-L8-A-1 |
n/a |
n/a |
Option_OutFlow_Distr |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
1 |
n/a |
n/a |
Option_Interlock_Distr |
Used only for envelop Dist or Sub HMI generation |
n/a |
n/a |
n/a |
n/a |
1 |
n/a |
n/a |
XenonRecuperation_FA_version |
logic production version |
n/a |
n/a |
n/a |
n/a |
n/a |
n/a |
1.0 |