Variable Description ATLRPC ATLTRT ATLCSC ATLTGC ATLMDT
HiLoFlow High and Low Flow control, valves YY6x23/1 and YY6x23/2 (1=High/Low control, 0=normal) 0 0 0 0 0
wago_node_nb number of wago nodes 2 2 2 2 3
has_parker_node has pasrker node (option valid? 1=yes, 0=No) 0 1 0 0 0
architecture two types of Architecture are possible A or B A A A A A
groups number of groups of racks 1 1 1 1 1
group1_racks number of racks in this group 5 3 2 8 15
group1_rack61_chls number of channels per rack of this group 32 18 16 14 17
rack61_label rack x label BR_RPC_L0_1 TRT End Cap L7 2-38 L4_2_53_(EI_CSC_L4_C1) EM_TGC_L0_C_1 EI_MDT_L4_C_1
group1_rack62_chls number of channels per rack of this group 24 48 16 28 16
rack62_label rack x label BR_RPC_L1_1 TRT Barrel L7 2-34 L4_2_35_(EI_CSC_L4_A1) EI_TGC_L4_C_1 EM_MDT_L1_C_1
group1_rack63_chls number of channels per rack of this group 16 18 n/a 8 16
rack63_label rack x label BR_RPC_L4_1 TRT End Cap L7 2-38 n/a EM_TGC_L4_C_1 EM_MDT_L7_C_1
group1_rack64_chls number of channels per rack of this group 24 n/a n/a 14 16
rack64_label rack x label BR_RPC_L7_1 n/a n/a EM-TGC-L8-C-1 EO_MDT_L5_C_1
group1_rack65_chls number of channels per rack of this group 32 n/a n/a 14 16
rack65_label rack x label BR_RPC_L8_1 n/a n/a EM_TGC_L0_A_1 EO_MDT_L8_C_1
m module backup facility PT5509 & Rotameter (option valid? 1=yes, 0=No) 0 0 0 0 0
o remote backup facility LEDs (option valid? 1=yes, 0=No) 0 0 0 0 0
p module backup facility gas bottle selection PSL5508 (option valid? 1=yes, 0=No) 0 0 0 0 0
a Individual purge line -inert gas selection valve HVxx62 (option valid? 1=yes, 0=No) 1 1 1 1 1
b1 Input pressure regulator PCVxx21 (option valid? 1=yes, 0=No) 1 0 1 1 1
b2 Input flowmeter FIVxx21 (option valid? 1=yes, 0=No) 0 0 0 0 0
c Input safety bubbler XBUBxx42 (option valid? 1=yes, 0=No) 1 1 1 1 0
d Input Top/Down selection valves YCxx44 (option valid? 1=yes, 0=No) 0 0 0 0 0
e Output pressure regulation valve PCVxx26 (option valid? 1=yes, 0=No) 1 0 0 1 1
f Channel isolation valves for rack flow cells measurement YVxx03 (option valid? 1=yes, 0=No) 0 0 0 0 1
g Output safety backup bubbler XBUBxx43 (option valid? 1=yes, 0=No) 1 1 1 1 0
h Rack backup output facility output valve YVxx72 and Bubbler XBUBxx74 (option valid? 1=yes, 0=No) 1 1 0 1 0
i Rack backup input facility safety valve YVxx71 (option valid? 1=yes, 0=No) 1 1 1 1 0
j Krypton soure input valve -YVxx56, output valve -YVxx57 and container (option valid? 1=yes, 0=No) 0 0 0 0 0
k Large detector and purge bubbler symbols for HMI only (option valid? 1=yes, 0=No) 0 0 0 0 0
l Input flow cells -FVxx01,-FExx02/c (option valid? 1=yes, 0=No) 1 1 1 1 1
z Output flow cells -FExx06/c (option valid? 1=yes, 0=No) 1 1 1 1 1
n chamber pressure transmitters PTxx04 (option valid? 1=yes, 0=No) 0 0 0 0 1
q chamber pressure transmitters (one per channel) PTxx04/c (option valid? 1=yes, 0=No) 1 0 0 0 0
r Input pressure devices -PIxx22 and -PTxx22 (option valid? 1=yes, 0=No) 0 0 0 0 0
s Near output pressure devices PIxx25 and PTxx25 (option valid? 1=yes, 0=No) 0 0 0 0 0
t Far output pressure devices PIxx26 and PTxx26 (option valid? 1=yes, 0=No) 1 1 0 1 1
u Output valve YVxx27 (option valid? 1=yes, 0=No) 1 1 0 1 1
v Safety purge flow indicatorZSLxx23 (option valid? 1=yes, 0=No) 0 0 0 0 0
y Output manifold differential pressure transmitter PDTxx25 (option valid? 1=yes, 0=No) 0 0 0 0 0
CriticalGas is AL or FS? AL AL AL AL AL
w module second backup facility gas bottle (option valid? 1=yes, 0=No) 0 0 0 0 0
Option100 output Group of Rack Pressure -PT6xx28 (option valid? 1=yes, 0=No) 0 0 0 0 0
test_LEDS Pulse to test the Front Panel LEDS (option implemented? 1=yes, 0=No) 0 0 0 0 0
parker_node_nb number of parker nodes n/a 1 0 1 1
group1_rack66_chls number of channels per rack of this group n/a n/a n/a 28 24
group1_rack67_chls number of channels per rack of this group n/a n/a n/a 8 22
group1_rack68_chls number of channels per rack of this group n/a n/a n/a 14 20
rack66_label rack x label n/a n/a n/a EM_TGC_L4_A_1 BR_MDT_L0_1
rack67_label rack x label n/a n/a n/a EI_TGC_L4_A_1 BR_MDT_L1_1
rack68_label rack x label n/a n/a n/a EM_TGC_L8_A_1 BR_MDT_L4_1
elmb_count number of ELMB Chassis (duplicated -to check if can be removed) n/a n/a n/a n/a 15
group1_rack69_chls number of channels per rack of this group n/a n/a n/a n/a 22
group1_rack70_chls number of channels per rack of this group n/a n/a n/a n/a 24
group1_rack71_chls number of channels per rack of this group n/a n/a n/a n/a 17
group1_rack72_chls number of channels per rack of this group n/a n/a n/a n/a 16
group1_rack73_chls number of channels per rack of this group n/a n/a n/a n/a 16
group1_rack74_chls number of channels per rack of this group n/a n/a n/a n/a 16
group1_rack75_chls number of channels per rack of this group n/a n/a n/a n/a 16
rack69_label rack x label n/a n/a n/a n/a BR_MDT_L7_1
rack70_label rack x label n/a n/a n/a n/a BR_MDT_L8_1
rack71_label rack x label n/a n/a n/a n/a EI_MDT_L4_A_1
rack72_label rack x label n/a n/a n/a n/a EM_MDT_L1_A_1
rack73_label rack x label n/a n/a n/a n/a EM_MDT_L7_A_1
rack74_label rack x label n/a n/a n/a n/a EO_MDT_L5_A_1
rack75_label rack x label n/a n/a n/a n/a EO_MDT_L8_A_1