Variable Description ATLAUX ATLCSC ATLMDT ATLRPC ATLTFC ATLTGC ATLTRT
has_MixerEnvelope additional mixer module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 0 0
wago_node_nb Number of wago modules 1 2 2 2 0 2 2
subdetector System Name AUX CSC MDT RPC TFC TGC TRT
sub_short System Short Name AUX CSC MDT RPC TFC TGC TRT
has_Mixer standard module optional (option valid? 1=yes, 0=no) 0 1 1 1 0 1 1
has_Pump standard module optional (option valid? 1=yes, 0=no) 0 0 1 1 0 1 1
has_Distribution standard module optional (option valid? 1=yes, 0=no) 0 1 1 1 0 1 1
has_PreDistribution standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 0 1
has_Purifier standard module optional (option valid? 1=yes, 0=no) 0 0 0 1 0 1 1
has_Absorber standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 0 0
has_Exhaust standard module optional (option valid? 1=yes, 0=no) 0 0 1 1 0 0 1
has_Analysis standard module optional (option valid? 1=yes, 0=no) 1 0 1 0 0 1 1
chains_count number of Analysis modules 4 n/a 1 n/a n/a 1 1
has_Humidifier standard module optional (option valid? 1=yes, 0=no) 0 1 0 1 0 0 0
has_Membrane standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 0 1
has_Recovery non standard module (valid only in CMS Recovery gas system) 0 0 0 0 0 0 0
has_Liquifier standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 1 0
has_Lucid non standard module (was used only in Atlas, removed after LS1) 0 0 0 0 0 0 0
has_IDFlushing non standard module (valid only in ATLAS) 1 0 0 0 0 0 0
has_IDFlushingN2 non standard module (valid only in CMS) 0 0 0 0 0 0 0
has_GasSystem standard module optional (option valid? 1=yes, 0=no) 0 1 1 1 0 1 1
has_Envelops standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 1 1
has_Environmental standard module optional (option valid? 1=yes, 0=no) 1 0 0 0 0 0 0
has_Primary standard module optional (option valid? 1=yes, 0=no) 1 0 0 0 0 0 0
has_CF4AbCF4 non standard module (used only in CMS CF4 Recovery gas system) 0 0 0 0 0 0 0
has_CF4AbCO2 non standard module (used only in CMS CF4 Recovery gas system) 0 0 0 0 0 0 0
has_CF4Membrane non standard module (used only in CMS CF4 Recovery gas system) 0 0 0 0 0 0 0
has_CF4Pump non standard module (used only in CMS CF4 Recovery gas system) 0 0 0 0 0 0 0
has_CF4Recovery non standard module (used only in CMS CF4 Recovery gas system) 0 0 0 0 0 0 0
has_GasSystemB non standard module (valid only in ATLAS TFC gas system) 0 0 0 0 1 0 0
has_DistributionB non standard module (valid only in ATLAS TFC gas system) 0 0 0 0 1 0 0
has_PumpB non standard module (valid only in ATLAS TFC gas system) 0 0 0 0 1 0 0
has_Injection non standard module (valid only in ATLAS TFC gas system) 0 0 0 0 1 0 0
has_Circulation non standard module (valid only in ATLAS TFC gas system) 0 0 0 0 1 0 0
has_TROpenSystem TROpen system part of TRT 0 0 0 0 0 0 1
has_XenonDirect valid only in TRT 0 0 0 0 0 0 1
dipManagerNumber Dip Manager Number 8 2 5 3 6 7 4
has_AnalysisO2 Analysis O2 FS alarm 0 0 0 0 0 0 0
has_AnalysisH2O Analysis H2O FS alarm 0 0 0 0 0 0 0
has_AnalysisCO2 Analysis CO2 FS alarm 0 0 0 0 0 0 0
has_AnalysisInfraRed Analysis Infrared FS alarm 0 0 0 0 0 0 0
SecChambPT 2nd chamber pressure transmitters PTxx04_2 used in Pump and Distribution(option valid? 1=yes, 0=No) 0 0 0 0 0 0 0
Option_BuffPressRegul Variable for trendtree element what depends from mixer`s same named variable n/a 0 0 0 n/a 0 1
Purifier_count Number of Purifier modules n/a 0 1 3 1 1 1
has_Distr_envelop has Distribution a Gas Envelop (1=yes, 0=no) n/a 0 0 0 0 1 0
has_SubDetect_envelop has Sub Detecotor a Gas Envelop (1=yes, 0=no) n/a 0 0 0 0 0 1
Distr_rack_nb Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 8 n/a
Distr_rack61_chls_nb Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 6 n/a
Distr_rack62_chls_nb Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 12 n/a
Distr_rack63_chls_nb Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 4 n/a
Distr_rack64_chls_nb Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 6 n/a
Distr_rack65_chls_nb Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 6 n/a
Distr_rack66_chls_nb Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 12 n/a
Distr_rack67_chls_nb Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 4 n/a
Distr_rack68_chls_nb Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 6 n/a
Distr_rack61_label Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a EM-TGC-L0-C-1 n/a
Distr_rack62_label Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a EI-TGC-L4-C-1 n/a
Distr_rack63_label Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a EM-TGC-L4-C-1 n/a
Distr_rack64_label Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a EM-TGC-L8-C-1 n/a
Distr_rack65_label Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a EM-TGC-L0-A-1 n/a
Distr_rack66_label Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a EM-TGC-L4-A-1 n/a
Distr_rack67_label Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a EI-TGC-L4-A-1 n/a
Distr_rack68_label Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a EM-TGC-L8-A-1 n/a
Option_OutFlow_Distr Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 1 n/a
Option_Interlock_Distr Used only for envelop Dist or Sub HMI generation n/a n/a n/a n/a n/a 1 n/a