Variable Description LHBAUX LHBGEM LHBMWP LHBOT LHBRI1 LHBRI2
has_MixerEnvelope additional mixer module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 0
wago_node_nb Number of wago modules 1 2 2 2 2 2
subdetector System Name AUX GEM MWP OT RI1 RI2
sub_short System Short Name AUX GEM MWP OT RI1 RI2
has_Mixer standard module optional (option valid? 1=yes, 0=no) 0 1 1 1 1 1
has_Pump standard module optional (option valid? 1=yes, 0=no) 0 1 1 1 1 1
has_Distribution standard module optional (option valid? 1=yes, 0=no) 0 1 1 1 1 1
has_PreDistribution standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 0
has_Purifier standard module optional (option valid? 1=yes, 0=no) 0 1 1 1 1 1
has_Absorber standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 0
has_Exhaust standard module optional (option valid? 1=yes, 0=no) 0 1 1 1 1 1
has_Analysis standard module optional (option valid? 1=yes, 0=no) 1 1 0 1 0 0
chains_count Number of Analysis modules 2 2 n/a 1 n/a n/a
has_Humidifier standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 0
has_Membrane standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 1 1
has_Recovery non standard module (valid only in CMS Recovery gas system) 0 0 0 0 0 0
has_Liquifier standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 1 0
has_Lucid non standard module (was used only in Atlas, removed after LS1) 0 0 0 0 0 0
has_IDFlushing non standard module (valid only in ATLAS) 0 0 0 0 0 0
has_IDFlushingN2 non standard module (valid only in CMS) 0 0 0 0 0 0
has_GasSystem standard module optional (option valid? 1=yes, 0=no) 0 1 1 1 1 1
has_Envelops standard module optional (option valid? 1=yes, 0=no) 0 0 0 0 0 0
has_Environmental standard module optional (option valid? 1=yes, 0=no) 1 0 0 0 0 0
has_Primary standard module optional (option valid? 1=yes, 0=no) 1 0 0 0 0 0
has_CF4AbCF4 non standard module (used only in CMS CF4 Recovery gas system) 0 0 0 0 0 0
has_CF4AbCO2 non standard module (used only in CMS CF4 Recovery gas system) 0 0 0 0 0 0
has_CF4Membrane non standard module (used only in CMS CF4 Recovery gas system) 0 0 0 0 0 0
has_CF4Pump non standard module (used only in CMS CF4 Recovery gas system) 0 0 0 0 0 0
has_CF4Recovery non standard module (used only in CMS CF4 Recovery gas system) 0 0 0 0 0 0
has_GasSystemB non standard module (valid only in ATLAS TFC gas system) 0 0 0 0 0 0
has_DistributionB non standard module (valid only in ATLAS TFC gas system) 0 0 0 0 0 0
has_PumpB non standard module (valid only in ATLAS TFC gas system) 0 0 0 0 0 0
has_Injection non standard module (valid only in ATLAS TFC gas system) 0 0 0 0 0 0
has_Circulation non standard module (valid only in ATLAS TFC gas system) 0 0 0 0 0 0
has_TROpenSystem non standard module (valid only for TROpen system part of TRT) 0 0 0 0 0 0
has_XenonDirect non standard module (valid only for TROpen system part of TRT) 0 0 0 0 0 0
dipManagerNumber Dip Manager Number 1 1 1 1 1 1
has_AnalysisO2 Analysis O2 FS alarm (option valid? 1=yes, 0=no) 0 1 0 0 0 0
has_AnalysisH2O Analysis H2O FS alarm (option valid? 1=yes, 0=no) 0 1 0 0 0 0
has_AnalysisCO2 Analysis CO2 FS alarm (option valid? 1=yes, 0=no) 0 0 0 0 0 0
has_AnalysisInfraRed Analysis Infrared FS alarm (option valid? 1=yes, 0=no) 0 0 0 0 0 0
Option_BuffPressRegul Variable for trendtree element what depends from mixer`s same named variable n/a 0 0 0 1 1
Purifier_count number of Purifier modules n/a 1 1 1 1 1
has_Distr_envelop Gas Envelop module type optional (option valid? 1=yes, 0=no) n/a 0 0 0 0 0
has_SubDetect_envelop Gas Envelop module type optional (option valid? 1=yes, 0=no) n/a 0 0 0 0 0